Product Description
Key Features
- Exact product identity: SIPLUS G120 PM240-2 IP20-FSC-U-400V based on 6SL3210-1PE23-3UL0, design FSC, product version FSC 15 kW.
- Supply and frequency: 380-480 V 3 AC +10/-10%, 47-63 Hz; input voltage type: AC.
- Overload ratings: Low overload: 15 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload: 11 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
- Output and performance: Output current, max.: 52 A; pulse frequency: 4 kHz; efficiency: 0.97.
- Construction and mounting: Dimensions: 355 x 140 x 165 mm (H x W x D); internal air cooling; cooling air flow: 0.019 m3/s.
- Protection and configuration: IP20; integrated braking chopper; no mains filter; supplied without CU and operating unit; released as of CU FW version V4.7 HF8.
Technical Summary
| Product number | 6AG1210-1PE23-2UL0 |
|---|---|
| Product type designation | PM240-2 |
| Based on | 6SL3210-1PE23-3UL0 |
| Supply | 380-480 V 3 AC +10/-10%, 47-63 Hz |
| Low-overload power | 15 kW |
| High-overload power | 11 kW |
| Output current, max. | 52 A |
| Pulse frequency | 4 kHz |
| Degree of protection | IP20 |
| Lifecycle | Active Product |
| Configuration exclusion | Without CU and operating unit |
Frequently Asked Questions
What exact variant is 6AG1210-1PE23-2UL0?
It is a SIPLUS G120 PM240-2 IP20-FSC-U-400V converter, design FSC, based on 6SL3210-1PE23-3UL0, with product version FSC 15 kW.
What supply data should be checked for this converter?
Check 380-480 V 3 AC +10/-10% and 47-63 Hz. The input voltage type is AC, and the mains filter is not present.
What overload ratings should be confirmed?
Low overload is 15 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload is 11 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
What is excluded from this configuration?
It is without CU and operating unit.