Product Description
Key Features
- Exact product identity: SIPLUS D455-2 DP/PN control unit, based on 6AU1455-2AD00-0AA0, with conformal coating.
- Motion control capacity: Multiple-axis system with ULTRA-HIGH Performance and up to 128 axes.
- Digital I/O configuration: Has 12 digital inputs and 16 digital I/Os; the I/Os can be parameterized as DI, DO, probe input (max. 16), or cam output (max. 8).
- Communication interfaces: Has 6 DRIVE-CLiQ, 2 USB, 2 Industrial Ethernet, 2 PROFIBUS, and 1 PROFINET interface with 3 ports onboard.
- Supply and installation data: Rated supply is 24 V; dimensions are 380 mm high, 50 mm wide, and 270 mm deep, with 4 300 g net weight.
- Lifecycle and supplied components: Product cancellation. The collected description includes a double fan/battery module and battery.
Applications
- Programmable motion control: Supports programmable motion control as a motion control system.
Technical Summary
| Product type | D455-2 DP/PN SIPLUS |
|---|---|
| Motion control performance class | ULTRA-HIGH Performance |
| Motion control system version | Multiple-axis system |
| Maximum number of axes | 128 |
| Digital inputs | 12 |
| Digital I/Os | 16 |
| DRIVE-CLiQ interfaces | 6 |
| PROFIBUS interfaces | 2; equidistant and isochronous; configurable as master or slave |
| PROFINET | 1 interface with 3 ports onboard; supports PROFINET IO with IRT and RT; configurable as PROFINET IO Controller and/or Device |
| Rated supply | 24 V |
| Operating temperature | 0 … 55 °C |
| Product lifecycle | Product cancellation |
Frequently Asked Questions
What order number should be confirmed for this SIPLUS control unit?
Confirm the complete order number 6AG1455-2AD00-4AA0 on the nameplate.
How many axes can the motion control system support?
The maximum number of axes is 128.
What I/O configuration does the unit have?
It has 12 digital inputs and 16 digital I/Os. The I/Os can be parameterized as DI, DO, probe input (max. 16), or cam output (max. 8).
Which communication interfaces are supplied?
The data shows 6 DRIVE-CLiQ, 2 USB, 2 Industrial Ethernet, 2 PROFIBUS, and 1 PROFINET interface with 3 ports onboard.
What lifecycle data should be considered?
The product lifecycle is Product cancellation; confirm quantity, destination, and condition preference for the request.