Product Description
Key Features
- Controller identity: Product type designation: CPU 1508S F; SIMATIC S7-1500 fail-safe Software Controller, single license for 1 install.
- Software and engineering: Software version: V21.9. Configurable/integrated with STEP 7 TIA Portal from V17.
- Memory: Integrated work memory: 12.5 Mbyte for the program, 100 Mbyte for data, and 50 Mbyte for the CPU function library of CPU Runtime. Integrated load memory: 1 024 Mbyte on PC mass storage.
- Interfaces and protocols: 2 PROFINET interfaces and 1 PROFIBUS interface; PROFINET IO Controller/device, PROFIBUS DP master, SIMATIC communication, Open IE communication, and OPC UA are supported.
- Safety performance: Highest safety class achievable in safety mode: PLe according to ISO 13849-1 and SIL 3 according to IEC 61508.
- Supplied configuration: Software and documentation on DVD, license key on USB flash drive, R-SW Class A, and 6 languages: de,en,it,fr,es,zh.
Applications
- Motion Control: Supports Motion Control technology objects, with 4 800 available Motion Control resources.
- PID control: Provides PID_Compact, PID_3Step, and PID-Temp controllers with integrated optimization.
- Industrial communication: Supports PROFINET IO Controller/device, PROFIBUS DP master, Open IE communication, and OPC UA functions.
Technical Summary
| Product type designation | CPU 1508S F |
|---|---|
| Software version | V21.9 |
| Engineering with STEP 7 TIA Portal | Configurable/integrated from V17 |
| Program work memory | 12.5 Mbyte |
| Data work memory | 100 Mbyte |
| Load memory | 1 024 Mbyte on PC mass storage |
| PROFINET interfaces | 2 |
| PROFIBUS interfaces | 1 |
| PROFINET IO Controller/device | Yes |
| Highest safety class | PLe according to ISO 13849-1; SIL 3 according to IEC 61508 |
Frequently Asked Questions
What exact Siemens order number should be confirmed for this Software Controller?
Confirm the complete nameplate order number 6ES7672-8FC01-0YA0.
Which software version is supplied?
The software version is V21.9, configurable/integrated with STEP 7 TIA Portal from V17.
What interfaces are included in the supplied configuration?
The source configuration includes 2 PROFINET interfaces and 1 PROFIBUS interface.
What is included with the license?
It includes software and documentation on DVD plus the license key on a USB flash drive; it is an R-SW Class A single license for 1 install.
What lifecycle information should be considered when checking this part?
The supplied lifecycle information is Announcement of product phase-out. Confirm the requested quantity, destination, and condition preference for the inquiry.