Product Description
Key Features
- Deterministic data exchange: Supports deterministic data exchange between max. 4 PN-Controllers per subnet and from subnet to subnet, plus PROFIsafe data exchange.
- PROFINET interfaces: Has 2 PROFINET interfaces and 2 ports via SIMATIC BusAdapter, with transmission up to 100 Mbit/s and an integrated switch.
- Supply and protection: Rated supply: 24 V DC; permissible range: 19.2 V to 28.8 V DC. Has reverse polarity protection and redundant power supply.
- Capacity and communication: Address space per module: max. 254 byte; address space per station: max. 1 440 byte; number of submodules per station: max. 116.
- Installation and firmware: Mounting: mounting rail 7.5 mm and 15 mm. Firmware version: V6.0; FW update possible: Yes.
- Supplied configuration: Delivery is without BusAdapter. Compatible BusAdapter options include BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, and BA LC / FC.
Applications
- Deterministic PROFINET data exchange: Supports deterministic data exchange between PN-Controllers per subnet and from subnet to subnet.
- PROFIsafe data exchange: Supports PROFIsafe data exchange.
- Local I/O and data-record coupling: Supports local coupling for I/O data and data records.
Technical Summary
| Product type | PN/PN coupler |
|---|---|
| Firmware version | V6.0 |
| Firmware update | Yes |
| Supply voltage, rated DC | 24 V |
| Permissible supply voltage, lower to upper limit | 19.2 V to 28.8 V DC |
| PROFINET interfaces | 2; via BusAdapter |
| Transmission rate, max. | 100 Mbit/s |
| Address space per module, max. | 254 byte; max. 254 bytes of input data and 253 bytes of output data |
| Address space per station, max. | 1 440 byte; per input / output |
| Number of submodules per station, max. | 116 |
| Mounting | Mounting rail 7.5 mm and 15 mm |
| Lifecycle | Active Product |
Frequently Asked Questions
What is the exact product type of 6ES7158-3AD10-0XA0?
It is a PN/PN coupler.
What supply voltage does 6ES7158-3AD10-0XA0 use?
Rated supply is 24 V DC, with a permissible range of 19.2 V to 28.8 V DC.
How does this model connect to PROFINET?
It has 2 PROFINET interfaces and 2 ports via SIMATIC BusAdapter; BusAdapter is not included.
Which firmware version does this model have?
Firmware version is V6.0, and FW update is possible.