Siemens Industrial Automation

3RW4446-6BC44

Siemens 3RW4446-6BC44 SIRIUS soft starter: 356 A at 400 V and 40 °C, 200 kW standard. Phased-out product; verify your legacy-part requirements.

Complete Product Information
Product Code
3RW4446-6BC44
Dimensions
43.2 × 34.8 × 37.6 cm
Weight
11.53 kg
Lifecycle
Start of final year of support
Availability
Check availability with quotation
Lead Time
Confirmed with quotation
Product Attachment
Download technical file

Availability, lead time, condition and warranty are confirmed for each quotation.

Product Information

Technical Product Information

Product Description

Key Features

  • Exact product identity: SIRIUS soft starter, Siemens 3RW4446-6BC44.
  • Rated performance: At 400 V and 40 °C: 356 A and 200 kW in standard circuit; 617 A and 355 kW in inside-delta circuit.
  • Control and protection: Has integrated bypass contact system, intrinsic device protection, motor overload protection, thermistor motor protection evaluation, external reset, and adjustable current limitation.
  • Electrical data: Operating voltage: 200 … 460 V AC. Control supply: 230 V AC at 50 Hz or 60 Hz.
  • Connections and mounting: Main current circuit: busbar connection. Auxiliary and control circuit: screw-type terminals. Mounting: screw fixing.
  • Lifecycle status: Phased-out product; product lifecycle: start of final year of support.

Technical Summary

Product designation Soft starter
Standard-circuit rated current at 40 °C 356 A
Standard-circuit rated power at 400 V and 40 °C 200 kW
Inside-delta rated current at 40 °C 617 A
Inside-delta rated power at 400 V and 40 °C 355 kW
Operating voltage 200 … 460 V AC
Control supply 230 V AC at 50 Hz or 60 Hz
Main current connection Busbar connection
Auxiliary and control connection Screw-type terminals
Front protection IP00; IP20 with box terminal/cover
Product lifecycle Start of final year of support

Frequently Asked Questions

What is the rated current of Siemens 3RW4446-6BC44?

The rated current is 356 A at 40 °C in standard circuit and 617 A at 40 °C in inside-delta circuit.

What motor power is specified at 400 V?

At 400 V and 40 °C, the rated motor power is 200 kW in standard circuit and 355 kW in inside-delta circuit.

How is the 3RW4446-6BC44 connected and mounted?

The main current circuit uses a busbar connection, the auxiliary and control circuit uses screw-type terminals, and mounting is by screw fixing.

What lifecycle information should be confirmed for this model?

The product is phased out, and its lifecycle is at the start of the final year of support. Confirm the exact installed part and required condition before making an inquiry.

Product Information

RFQ Information

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

01Which product reference should I send?

Send the complete model, order number or MLFB shown on the product. Include the hardware version when it matters.

02How are supply terms confirmed?

Availability, condition, lead time, warranty and delivery terms are stated for the specific quotation.

03What helps with replacement requests?

Share the installed model, application, electrical and mechanical requirements, communication interface and a clear nameplate photo.

Product RFQ

Send the Details Needed for a Quotation

Use the form for the product model, quantity and contact details. Add the destination and technical questions in the message.

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

Email Your Requirement

* Email is required. Other fields are optional, but more detail helps us respond accurately.

Request a Quote