Siemens 3RW4036-1BB14 SIRIUS soft starter with 45 A rated current, 22 kW at 400 V, 200 ... 480 V operating voltage, and screw terminals. Check a legacy-part verification inquiry.

Complete Product Information
Product Code
3RW4036-1BB14
Dimensions
19.6 × 7.1 × 16.8 cm
Weight
1.27 kg
Lifecycle
Active Product
Availability
Check availability with quotation
Lead Time
Confirmed with quotation
Product Attachment
Download technical file

Availability, lead time, condition and warranty are confirmed for each quotation.

Product Information

Technical Product Information

Product Description

Key Features

  • Rated current and motor power: Rated current: 45 A at 40 °C. Motor power: 22 kW at 400 V in the standard circuit at 40 °C.
  • Operating and control supply: Operating voltage: 200 … 480 V in the standard circuit. Control supply: 110 … 230 V AC/DC.
  • Soft starter functions: Has an integrated bypass contact system, thyristors, intrinsic device protection, motor overload protection, external reset, and adjustable current limitation.
  • Connection and mounting: Main, auxiliary, and control circuits use screw-type terminals. Fastening: screw and snap-on mounting. Size: S2.
  • Electrical ratings: Insulation voltage rated value: 600 V. Blocking voltage of the thyristor maximum: 1 600 V. Continuous operating current: 115 % of Ie at 40 °C.
  • Protection and lifecycle: Front protection class: IP20 according to IEC 60529. Lifecycle: Active Product.

Technical Summary

Product Siemens 3RW4036-1BB14 SIRIUS soft starter S2
Rated current at 40 °C 45 A
Motor power at 400 V 22 kW
Operating voltage 200 … 480 V
Control supply 110 … 230 V AC/DC
Operating frequency 50 … 60 Hz
Connection Screw-type terminals for main, auxiliary, and control circuits
Mounting Screw and snap-on mounting
Front protection IP20 according to IEC 60529
Lifecycle Active Product

Frequently Asked Questions

What rated current and motor power does Siemens 3RW4036-1BB14 have?

It has a rated current of 45 A at 40 °C and supports 22 kW at 400 V in the standard circuit at 40 °C.

What operating and control supply voltages should be confirmed?

The operating voltage is 200 … 480 V in the standard circuit. The control supply is 110 … 230 V AC/DC.

What terminals and mounting method does this soft starter use?

It uses screw-type terminals for the main, auxiliary, and control circuits, with screw and snap-on mounting.

What protection and lifecycle data should be checked for this exact model?

The front protection class is IP20 according to IEC 60529, and the lifecycle is Active Product. Confirm the installed configuration and condition requirement for the inquiry.

Product Information

RFQ Information

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

01Which product reference should I send?

Send the complete model, order number or MLFB shown on the product. Include the hardware version when it matters.

02How are supply terms confirmed?

Availability, condition, lead time, warranty and delivery terms are stated for the specific quotation.

03What helps with replacement requests?

Share the installed model, application, electrical and mechanical requirements, communication interface and a clear nameplate photo.

Product RFQ

Send the Details Needed for a Quotation

Use the form for the product model, quantity and contact details. Add the destination and technical questions in the message.

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

Email Your Requirement

* Email is required. Other fields are optional, but more detail helps us respond accurately.

Request a Quote