Product Description
Key Features
- Rated power and overload: Rated power: 0.55 kW (LO) and 0.37 kW (HO). LO: 150% for 3s, 110% for 57s, 100% for 240s; HO: 200% for 3s, 150% for 57s, 100% for 240s.
- Electrical input and output: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, rated voltage 400V IEC | 480V NEC, maximum output current 2.60 A.
- I/O and safety: The unfiltered external 24V I/O interface has 6DI, 2DO, 1AI and 1AO, with 1 fail-safe digital input. Safe Torque Off is integrated.
- Communication and control: Communication: PROFINET, EtherNet/IP. Supported control techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control.
- Connections and protection: Line-side, motor-end and DC-link connections use plug-in screw terminals. Protection: IP20 / UL open type. Frame size: FSAA.
- Lifecycle: Lifecycle status: Active Product.
Technical Summary
| Product | Siemens 6SL3210-1KE11-8UF2, SINAMICS G120C compact converter |
|---|---|
| Input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Rated power (LO) | 0.55 kW | 0.75 hp |
| Rated power (HO) | 0.37 kW | 0.50 hp |
| Maximum output current | 2.60 A |
| Communication | PROFINET, EtherNet/IP |
| I/O interface | 6DI, 2DO, 1AI, 1AO; 1 fail-safe digital input |
| Safe Torque Off | Integrated |
| Control techniques | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| Connections | Plug-in screw terminals |
| Protection | IP20 / UL open type |
Frequently Asked Questions
What exact model should be confirmed for this Siemens drive?
Confirm order number 6SL3210-1KE11-8UF2 and the SINAMICS G120C identity.
What are the rated input and output values?
Input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz. Rated output power is 0.55 kW (LO) or 0.37 kW (HO).
Which communication and I/O interfaces are supplied?
Communication is PROFINET and EtherNet/IP. The I/O interface has 6DI, 2DO, 1AI and 1AO, plus 1 fail-safe digital input.
What connection and protection details should be checked?
Check the plug-in screw terminals, FSAA frame size and IP20 / UL open type protection.