Product Description
Key Features
- Rated power and overload: Rated power: 0.55 kW (LO) and 0.37 kW (HO). Low overload: 150% for 3s, 110% for 57s, 100% for 240s; high overload: 200% for 3s, 150% for 57s, 100% for 240s.
- Input and output ratings: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, rated voltage 400V IEC | 480V NEC, maximum output current 2.60 A.
- I/O and safety: The unfiltered external 24V I/O interface has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input, and 1 non-isolated analog output. Safe Torque Off is integrated.
- Communication and control: Fieldbus: USS/MODBUS RTU. Supported control techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
- Connections and installation: Line side, motor end, and DC link use plug-in screw terminals. Frame size: FSAA. Width: 73 mm (2.87 in); depth: 155 mm (6.10 in).
- Protection and lifecycle: Degree of protection: IP20 / UL open type. Product lifecycle: Active Product.
Technical Summary
| Product | Siemens 6SL3210-1KE11-8UB2 SINAMICS G120C |
|---|---|
| Product lifecycle | Active Product |
| Input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Rated power (LO) | 0.55 kW | 0.75 hp |
| Rated power (HO) | 0.37 kW | 0.50 hp |
| Max. output current | 2.60 A |
| I/O interface | 6DI, 2DO, 1AI, 1AO, 1 fail-safe digital input; external 24V |
| Communication | USS/MODBUS RTU |
| Protection | IP20 / UL open type |
| Frame size | FSAA |
| Installation connections | Plug-in screw terminals |
Frequently Asked Questions
What exact model should be confirmed for this Siemens drive?
Confirm order number 6SL3210-1KE11-8UB2 and the SINAMICS G120C product identity.
What are the input ratings?
Input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
What I/O configuration does it have?
It has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input, and 1 non-isolated analog output.
Which communication interface is supplied?
The communication interface is USS/MODBUS RTU.
What protection and mounting dimensions should be checked?
Protection is IP20 / UL open type. Frame size is FSAA; width is 73 mm (2.87 in) and depth is 155 mm (6.10 in).