Siemens Industrial Automation

6ES7134-6PA01-0CU0

6ES7134-6PA01-0CU0 is a SIMATIC ET 200SP AI Energy Meter CT HF for 1 A or 5 A current transformers, with line analysis, V8.0 firmware, and channel diagnostics. Check a legacy-part request.

Complete Product Information
Product Code
6ES7134-6PA01-0CU0
Dimensions
7.7 × 6.5 × 2.3 cm
Weight
0.055 kg
Lifecycle
Active Product
Availability
Check availability with quotation
Lead Time
Confirmed with quotation
Product Attachment
Download technical file

Availability, lead time, condition and warranty are confirmed for each quotation.

Product Information

Technical Product Information

Product Description

Key Features

  • Product identity: SIMATIC ET 200SP analog input module with product type designation AI Energy Meter CT HF.
  • Current transformer input: Supports current measurement with a 1 A or 5 A current transformer; maximum 4 current measurements.
  • Measurement functions: Measures voltage, current, energy, frequency, power, active power, reactive power, power factor, harmonics, THD, voltage dip, and voltage swell.
  • Line analysis: Provides line analysis with monitoring of instantaneous and half-wave values, plus THD measurement and harmonics for current and voltage.
  • Supply and BaseUnit: Rated supply voltage is 24 V DC, with a permissible range from 19.2 V to 28.8 V DC. Usable BaseUnit: BU type U0.
  • Firmware and diagnostics: Firmware version V8.0; FW update possible. Diagnostic alarm, limit value alarm, hardware interrupt, and channel diagnostics are available.

Applications

  • Electrical measurement: Measures voltage, current, energy, frequency, power, active energy, reactive energy, and power factor.
  • Line analysis: Performs line analysis, including THD measurement, harmonics, voltage dip, and voltage swell detection.

Technical Summary

Product type AI Energy Meter CT HF
Firmware version V8.0
Current transformer input 1 A or 5 A current transformer; maximum 4 current measurements
Rated supply voltage 24 V DC
Permissible supply voltage 19.2 V to 28.8 V DC
Usable BaseUnit BU type U0
Supported power supply systems TT, TN, IT
Communication engineering STEP 7 V16 or higher with HSP; V5.5 SP3 or higher; PROFIBUS GSD Revision 3 and 5 and higher; PROFINET GSD V2.3
Cycle time, all channels 50 ms; time for consistent update of all measured and calculated values
Sampling frequency, max. 2 048 kHz
Mounting position any

Frequently Asked Questions

What is the exact order number and product type?

The exact order number is 6ES7134-6PA01-0CU0, and the product type designation is AI Energy Meter CT HF.

Which current transformer inputs should be confirmed?

Confirm whether the installed configuration uses a 1 A or 5 A current transformer; current measurement is available for up to 4 measurements.

Which firmware version does this module have?

Firmware version is V8.0, and FW update is possible.

Which BaseUnit is usable for this module?

The usable BaseUnit is BU type U0.

Product Information

RFQ Information

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

01Which product reference should I send?

Send the complete model, order number or MLFB shown on the product. Include the hardware version when it matters.

02How are supply terms confirmed?

Availability, condition, lead time, warranty and delivery terms are stated for the specific quotation.

03What helps with replacement requests?

Share the installed model, application, electrical and mechanical requirements, communication interface and a clear nameplate photo.

Product RFQ

Send the Details Needed for a Quotation

Use the form for the product model, quantity and contact details. Add the destination and technical questions in the message.

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

Email Your Requirement

* Email is required. Other fields are optional, but more detail helps us respond accurately.

Request a Quote