Product Description
Key Features
- Rated power and overload: Rated power is 30.00 kW | 30.00 hp at low overload and 22.00 kW | 25.00 hp at high overload. Low overload: 150% for 3 s, 110% for 57 s, 100% for 240 s; high overload: 200% for 3 s, 150% for 57 s, 100% for 240 s.
- Input and output ratings: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, 400V IEC | 480V NEC, with maximum output current of 87.00 A.
- Communication and I/O: Integrated fieldbus: PROFINET. Communication also supports EtherNet/IP. I/O includes 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog/digital input, and 1 non-isolated analog output.
- Control and feedback: Supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control. Vector control with sensor, encoderless torque control, and torque control with encoder are not supported.
- Connections and cooling: Line-side and motor-end connections use screw-type terminals. Signal conductors accept 0.15 … 1.50 mm2 (AWG 24 … AWG 16); line-side and DC-link conductors accept 10.00 … 35.00 mm2 (AWG 8 … AWG 2). Cooling uses an integrated fan.
- Protection and mechanical data: Protection: IP20 / UL open type. Frame size: FSD. Dimensions: 200 mm width and 237 mm depth. Net weight: 18.80 kg (41.45 lb).
Technical Summary
| Rated power (LO) | 30.00 kW | 30.00 hp |
|---|---|
| Rated power (HO) | 22.00 kW | 25.00 hp |
| Input voltage | 380 … 480 V +10 % -20 % |
| Line frequency | 47 … 63 Hz |
| Communication | PROFINET, EtherNet/IP |
| I/O | 6 digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog/digital input, 1 non-isolated analog output |
| Control techniques | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| Protection | IP20 / UL open type |
| Frame size | FSD |
| Lifecycle | Active Product |
Frequently Asked Questions
What input rating should be confirmed for 6SL3210-1KE26-0AF1?
Input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
Which communication interfaces are supplied?
The drive has integrated PROFINET and also supports EtherNet/IP.
What connection details should be checked for the installed configuration?
Line-side, motor-end, DC-link, and PE connections use screw-type terminals. The DC-link line length is maximum 10 m (32.81 ft), and maximum shielded motor cable length is 200 m (656.17 ft).
What is the lifecycle status of this exact order number?
The supplied lifecycle value is Active Product.