Siemens Industrial Automation

6AG2241-1CH30-1XB0

Siemens 6AG2241-1CH30-1XB0 SIPLUS S7-1200 CB 1241 RS 485 with conformal coating, RS-485, Freeport support, and Active Product lifecycle data. Check this exact legacy-part request.

Complete Product Information
Product Code
6AG2241-1CH30-1XB0
Dimensions
8.1 × 5 × 3 cm
Weight
0.034 kg
Lifecycle
Active Product
Availability
Check availability with quotation
Lead Time
Confirmed with quotation
Product Attachment
Download technical file

Availability, lead time, condition and warranty are confirmed for each quotation.

Product Information

Technical Product Information

Product Description

Key Features

  • Product identity: SIPLUS S7-1200 CB 1241 RS 485, product type designation CB 1241 RS 485, based on 6ES7241-1CH30-1XB0.
  • RS-485 connection: RS-485 with terminal block; cable length max. 1 000 m for point-to-point connection.
  • Protocol support: Supports Freeport, ASCII, Modbus RTU master, Modbus RTU device, and USS. ASCII and USS are available as library functions.
  • Environmental configuration: Conformal coating; horizontal installation ambient temperature -25 °C to 60 °C, with +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155).
  • Protection and dimensions: IP20; width 38 mm, height 62 mm, depth 21 mm; weight approx. 40 g.

Technical Summary

Product type CB 1241 RS 485
Based on 6ES7241-1CH30-1XB0
Connection RS-485, terminal block
Protocol drivers Freeport; ASCII; Modbus RTU master; Modbus RTU device; USS
Input current from backplane bus 5 V DC, typ. 50 mA
Power loss, typ. 1.5 W
IP degree of protection IP20
Operating temperature, horizontal installation -25 °C to 60 °C; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155)
Conformal coating Yes; Class 2 for high reliability acc. to EN 61086
Product lifecycle Active Product

Frequently Asked Questions

What exact Siemens model is this module?

It is Siemens 6AG2241-1CH30-1XB0, SIPLUS S7-1200 CB 1241 RS 485, product type designation CB 1241 RS 485, based on 6ES7241-1CH30-1XB0.

Which protocols does the CB 1241 RS 485 support?

It supports Freeport, ASCII, Modbus RTU master, Modbus RTU device, and USS. ASCII and USS are available as library functions.

What connection and cable length does it have?

It has an RS-485 terminal block and supports a maximum cable length of 1 000 m for point-to-point connection.

What installation temperature limits should be confirmed?

For horizontal installation, the ambient temperature is -25 °C to 60 °C, with +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155). For vertical installation, it is -25 °C to 50 °C.

Product Information

RFQ Information

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

01Which product reference should I send?

Send the complete model, order number or MLFB shown on the product. Include the hardware version when it matters.

02How are supply terms confirmed?

Availability, condition, lead time, warranty and delivery terms are stated for the specific quotation.

03What helps with replacement requests?

Share the installed model, application, electrical and mechanical requirements, communication interface and a clear nameplate photo.

Product RFQ

Send the Details Needed for a Quotation

Use the form for the product model, quantity and contact details. Add the destination and technical questions in the message.

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

Email Your Requirement

* Email is required. Other fields are optional, but more detail helps us respond accurately.

Request a Quote