Product Description
Key Features
- Rated power and overload: Rated power: 15.00 kW | 20.00 hp (LO) and 11.00 kW | 15.00 hp (HO). LO: 150% for 3s, 110% for 57s, 100% for 240s; HO: 200% for 3s, 150% for 57s, 100% for 240s.
- Input and output ratings: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, 400V IEC | 480V NEC, with maximum output current of 50.00 A.
- I/O and communication: I/O: 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog/digital input, and 1 non-isolated analog output. Communication: PROFINET, EtherNet/IP.
- Control and filter: Supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control. Integrated filter: Class A.
- Connections and installation: Line-side and motor-end versions use plug-in screw terminals. Signal cable conductor cross-section: 0.15 … 1.50 mm2 (AWG 24 … AWG 16); line-side and DC-link conductor cross-section: 6.00 … 16.00 mm2 (AWG 10 … AWG 6).
- Mechanical variant and protection: Frame size: FSC. Dimensions: 140 mm (5.51 in) width × 205 mm (8.19 in) depth. Degree of protection: IP20 / UL open type. Net weight: 4.40 kg (9.70 lb).
Technical Summary
| Rated power (LO) | 15.00 kW | 20.00 hp |
|---|---|
| Rated power (HO) | 11.00 kW | 15.00 hp |
| Input voltage | 380 … 480 V +10 % -20 % |
| Input frequency | 47 … 63 Hz |
| Communication | PROFINET, EtherNet/IP |
| I/O configuration | 6DI, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog/digital input, 1 non-isolated analog output |
| Output frequency for vector control | 0 … 240 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Line-side connection | Plug-in screw terminals; 6.00 … 16.00 mm2 (AWG 10 … AWG 6) |
| Degree of protection | IP20 / UL open type |
| Frame size | FSC |
Frequently Asked Questions
What is the exact model and supplied product family?
The exact model is 6SL3210-1KE23-2AF1 from the SINAMICS G120C family.
What input rating should be confirmed for this configuration?
Input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
Which communication interface and I/O are supplied?
Communication is PROFINET and EtherNet/IP. I/O includes 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog/digital input, and 1 non-isolated analog output.
Which connectors should be checked during installed-part matching?
The line side and motor end use plug-in screw terminals. The DC link for the braking resistor also uses plug-in screw terminals.