Product Description
Key Features
- Exact product identity: Product type: PM240-2; product version: FSD 30 kW; design: FSD.
- Input supply: Input voltage: 380-480 V 3 AC +10/-20%, 47-63 Hz; input voltage type: AC.
- Power output: Active power output: 30 kW with low overload and 22 kW with high overload; apparent power output: 41.6 kVA.
- Overload performance: Low overload: 1.1x rated output current for 57 s and 1.5x for 3 s, with a cycle time of 300 s. High overload: 1.5x output current rating for 57 s and 2x for 3 s, with a cycle time of 300 s.
- Protection and cooling: IP degree of protection: IP20. Cooling method: internal air cooling; cooling air flow: 0.055 m3/s.
- Configuration and lifecycle: Based on 6SL3210-1PE26-0UL0, with conformal coating, without CU and operating unit. Active Product; released as of CU FW version V4.7 HF8.
Technical Summary
| Product type | PM240-2 |
|---|---|
| Product version | FSD 30 kW |
| Input supply | 380-480 V 3 AC +10/-20%, 47-63 Hz |
| Active power output, low overload | 30 kW |
| Active power output, high overload | 22 kW |
| Output current, max. | 90 A |
| Pulse frequency | 4 kHz |
| Efficiency | 0.98 |
| Protection | IP20 |
| Cooling | Internal air cooling; 0.055 m3/s |
| Lifecycle | Active Product |
Frequently Asked Questions
How can I verify the exact 6AG1210-1PE26-2UL0 variant?
Confirm the complete order number, PM240-2 product type, FSD 30 kW product version, and FSD design.
What supply does this converter use?
It uses 380-480 V 3 AC +10/-20% at 47-63 Hz, with AC input voltage.
What overload ratings should be checked?
Low overload is 30 kW and high overload is 22 kW. The duty-cycle details are 1.1x for 57 s and 1.5x for 3 s at low overload, and 1.5x for 57 s and 2x for 3 s at high overload, each with a 300 s cycle time.
What is included in this configuration?
It has conformal coating and an integrated braking chopper. It is without CU and operating unit.