Siemens Industrial Automation

6AG1210-1PE26-2UL0

6AG1210-1PE26-2UL0 is a SIPLUS G120 PM240-2 FSD 30 kW converter with IP20, conformal coating, integrated braking chopper, and 380-480 V 3 AC input. Check this exact legacy-part request.

Complete Product Information
Product Code
6AG1210-1PE26-2UL0
Dimensions
49.5 × 35.6 × 30 cm
Weight
18.3 kg
Lifecycle
Active Product
Availability
Check availability with quotation
Lead Time
Confirmed with quotation
Product Attachment
Download technical file

Availability, lead time, condition and warranty are confirmed for each quotation.

Product Information

Technical Product Information

Product Description

Key Features

  • Exact product identity: Product type: PM240-2; product version: FSD 30 kW; design: FSD.
  • Input supply: Input voltage: 380-480 V 3 AC +10/-20%, 47-63 Hz; input voltage type: AC.
  • Power output: Active power output: 30 kW with low overload and 22 kW with high overload; apparent power output: 41.6 kVA.
  • Overload performance: Low overload: 1.1x rated output current for 57 s and 1.5x for 3 s, with a cycle time of 300 s. High overload: 1.5x output current rating for 57 s and 2x for 3 s, with a cycle time of 300 s.
  • Protection and cooling: IP degree of protection: IP20. Cooling method: internal air cooling; cooling air flow: 0.055 m3/s.
  • Configuration and lifecycle: Based on 6SL3210-1PE26-0UL0, with conformal coating, without CU and operating unit. Active Product; released as of CU FW version V4.7 HF8.

Technical Summary

Product type PM240-2
Product version FSD 30 kW
Input supply 380-480 V 3 AC +10/-20%, 47-63 Hz
Active power output, low overload 30 kW
Active power output, high overload 22 kW
Output current, max. 90 A
Pulse frequency 4 kHz
Efficiency 0.98
Protection IP20
Cooling Internal air cooling; 0.055 m3/s
Lifecycle Active Product

Frequently Asked Questions

How can I verify the exact 6AG1210-1PE26-2UL0 variant?

Confirm the complete order number, PM240-2 product type, FSD 30 kW product version, and FSD design.

What supply does this converter use?

It uses 380-480 V 3 AC +10/-20% at 47-63 Hz, with AC input voltage.

What overload ratings should be checked?

Low overload is 30 kW and high overload is 22 kW. The duty-cycle details are 1.1x for 57 s and 1.5x for 3 s at low overload, and 1.5x for 57 s and 2x for 3 s at high overload, each with a 300 s cycle time.

What is included in this configuration?

It has conformal coating and an integrated braking chopper. It is without CU and operating unit.

Product Information

RFQ Information

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

01Which product reference should I send?

Send the complete model, order number or MLFB shown on the product. Include the hardware version when it matters.

02How are supply terms confirmed?

Availability, condition, lead time, warranty and delivery terms are stated for the specific quotation.

03What helps with replacement requests?

Share the installed model, application, electrical and mechanical requirements, communication interface and a clear nameplate photo.

Product RFQ

Send the Details Needed for a Quotation

Use the form for the product model, quantity and contact details. Add the destination and technical questions in the message.

When contacting us by email, include the model or part number, quantity, brand, specifications and destination. Product or nameplate photos can help identify the requested item.

Email Your Requirement

* Email is required. Other fields are optional, but more detail helps us respond accurately.

Request a Quote