Product Description
Key Features
- Exact model and lifecycle: Product: Siemens 6SL3210-1KE14-3AP2. Family: SINAMICS G120C. Lifecycle: Active Product.
- Input and output ratings: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Rated output power: 1.50 kW | 2.00 hp (LO) and 1.10 kW | 1.50 hp (HO).
- Interfaces and I/O: Communication: PROFIBUS DP. I/O: 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input and 1 non-isolated analog output.
- Control and safety: Control includes V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control. Safe Torque Off is integrated.
- Connections and installation: Line side, motor end and DC link use plug-in screw terminals. Frame size: FSAA. Dimensions: 73 mm width and 155 mm depth. Net weight: 1.40 kg (3.09 lb).
- Protection and filter: Protection: IP20 / UL open type. Integrated filter: Class A.
Technical Summary
| Product | Siemens 6SL3210-1KE14-3AP2 |
|---|---|
| Family | SINAMICS G120C |
| Lifecycle | Active Product |
| Input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Rated output power (LO) | 1.50 kW | 2.00 hp |
| Rated output power (HO) | 1.10 kW | 1.50 hp |
| Communication | PROFIBUS DP |
| I/O | 6 DI, 1 fail-safe DI, 1 relay changeover contact, 1 transistor output, 1 differential AI, 1 non-isolated AO |
| Protection | IP20 / UL open type |
| Frame size | FSAA |
| Integrated filter | Class A |
Frequently Asked Questions
What exact order number should be confirmed for this SINAMICS G120C converter?
Confirm Siemens order number 6SL3210-1KE14-3AP2 and the SINAMICS G120C family.
Which communication interface and I/O configuration does it have?
It has PROFIBUS DP, 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input and 1 non-isolated analog output.
What are the supplied input and output ratings?
Input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz. Rated output power is 1.50 kW | 2.00 hp (LO) or 1.10 kW | 1.50 hp (HO).
What protection and mounting details should be checked?
Check IP20 / UL open type protection, FSAA frame size, 73 mm width, 155 mm depth and plug-in screw terminals.