Product Description
Key Features
- Exact product identity: Product type designation: KP32F PN. The panel has 32 function keys and 32 short-stroke keys with parameterizable keys.
- Digital I/O capacity: The configuration has 32 digital inputs and 16 digital outputs. Total inputs and outputs are max. 32; the outputs have short-circuit protection.
- PROFINET and PROFIsafe interfaces: There are 2 industrial Ethernet interfaces and 2 PROFINET interfaces, including a switch. PROFINET and PROFIsafe are supported; PROFIsafe supports 2x SIL 3 (two-channel) or 4x SIL 2 (single-channel) emergency stop sensors.
- LED and direct-key functions: The panel has 8 DP direct LEDs with adjustable brightness, 5 LED color modes—red, green, blue, yellow, white—and 32 direct keys.
- Supply and output data: Supply voltage: 24 V DC, with 20.4 V to 28.8 V permissible range. Output voltage: 24 V DC, non-isolated; current per channel is max. 100 mA and current per group is max. 800 mA.
- Front protection and mounting: Front protection is IP65 and rear protection is IP20. Mounting uses a mounting clip with vertical mounting position; front mounting and portrait or landscape mounting are possible.
Technical Summary
| Product type designation | KP32F PN |
|---|---|
| Short-stroke keys | 32 |
| Digital inputs | 32 |
| Digital outputs | 16 |
| PROFINET interfaces | 2; Incl. switch |
| PROFIsafe | Yes; 2x SIL 3 (two-channel) or 4x SIL 2 (single-channel) emergency stop sensors |
| Supply voltage | 24 V DC; 20.4 V to 28.8 V permissible range |
| Output current per channel, max. | 100 mA |
| Mounting type | Mounting clip |
| Protection | IP65 at the front; IP20 at the rear |
Frequently Asked Questions
What order number and product type should be confirmed for this HMI key panel?
Confirm order number 6AV3688-3EH47-0AX0 and product type designation KP32F PN.
How many inputs and outputs does the KP32F PN have?
It has 32 digital inputs and 16 digital outputs. Total inputs and outputs are max. 32.
Which network interfaces are available?
It has 2 industrial Ethernet interfaces and 2 PROFINET interfaces, including a switch.
What mounting and protection details should be checked?
Mounting uses a mounting clip. Front mounting is possible, and front protection is IP65 while rear protection is IP20.