- Exact product identity: SIMATIC ET 200SP BusAdapter BA-SEND BA1XFC; product type designation: BA-Send 1x FC.
- ET connection interface: Has 1 ET connection interface with FC (FastConnect).
- HW functional status: HW functional status: From FS05.
- Cable length: Cu conductors: 15 m; from IM firmware V3.3: between BA-send and the first ET-CONNECTION bus node and between all other bus nodes.
- Installation dimensions and weight: Dimensions: 20 mm width, 69.5 mm height, and 59 mm depth. Weight, approx.: 44 g.
- Lifecycle and environmental data: Product lifecycle: Active Product. Environmental product declaration: Yes.
Applications
- ET connection: Provides 1 FastConnect connection for an ET connection in a SIMATIC ET 200SP configuration.
Technical Summary
| Product name | 6ES7193-6AS00-0AA0 |
|---|---|
| Product type designation | BA-Send 1x FC |
| ET connection interfaces | 1 |
| FastConnect | Yes |
| HW functional status | From FS05 |
| Operating ambient temperature, horizontal installation | -30 °C to 60 °C |
| Operating ambient temperature, vertical installation | -30 °C to 50 °C |
| Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual |
Frequently Asked Questions
What is the exact order number and product type?
The exact order number is 6ES7193-6AS00-0AA0, and the product type designation is BA-Send 1x FC.
How many ET connection interfaces does the BusAdapter have?
It has 1 ET connection interface with FC (FastConnect).
What cable length is specified for Cu conductors?
The cable length is 15 m; from IM firmware V3.3, this applies between BA-send and the first ET-CONNECTION bus node and between all other bus nodes.
What installation temperatures are specified?
For horizontal installation, the ambient temperature during operation is -30 °C to 60 °C. For vertical installation, it is -30 °C to 50 °C.
What lifecycle status should be verified for this part?
The lifecycle status is Active Product. Confirm the order number and required configuration for the request.