Product Description
Key Features
- CANopen and control functions: Supports CANopen, V/f linear, square-law and parameterizable control, V/f with flux current control (FCC), V/f ECO linear and square-law, sensorless vector control, vector control with sensor, encoderless torque control, and torque control with encoder.
- Digital and analog I/O: Has 15 standard digital inputs, 3 fail-safe digital inputs using 2 × DI Standard, 2 relay changers, 2 differential analog/digital inputs and 2 non-isolated analog outputs.
- Encoder and safety interfaces: Has a D-CLiQ+HTL/TTL/SSI encoder interface and Resolver/HTL via terminal. Safety Integrated functions include STO, SBC and SS1; additional safety functions require the EXTENDED SAFETY license.
- Electrical supply: Supply via the Power Module: DC 24 V. External power supply: DC 20 … 29 V. Maximum power consumption: 2.00 A. Power loss: 12.00 W.
- Interfaces and protection: Has USB and SD/MMC interfaces. Degree of protection: IP20 / UL open type.
- Product lifecycle: Product lifecycle: Announcement of product phase-out.
Applications
- Basic positioning: The Basic positioner EPOS is supported via a license for extended functions.
Technical Summary
| Product | 6SL3246-0BA22-1CA0 |
|---|---|
| Control unit | SINAMICS G120 Control Unit CU250S-2 CAN |
| Communication | CANopen |
| Standard digital inputs | 15 |
| Fail-safe digital inputs | 3 (Use of 2 × DI Standard) |
| Analog / digital inputs | 2 (Differential input) |
| Analog outputs | 2 (Non-isolated output) |
| Encoder interface | D-CLiQ+HTL/TTL/SSI Encoder; Resolver/HTL via terminal |
| Supply via the Power Module | DC 24 V |
| External power supply | DC 20 … 29 V |
| Degree of protection | IP20 / UL open type |
| Product lifecycle | Announcement of product phase-out |
Frequently Asked Questions
What exact model and control unit are covered?
The exact model is 6SL3246-0BA22-1CA0, a SINAMICS G120 Control Unit CU250S-2 CAN.
Which communication interface does the control unit have?
It has CANopen communication, plus USB and SD/MMC interfaces.
What feedback interfaces are available?
The encoder interface supports D-CLiQ+HTL/TTL/SSI, and Resolver/HTL is available via terminal.
What digital and analog I/O configuration should be confirmed?
The configuration has 15 standard digital inputs, 3 fail-safe digital inputs using 2 × DI Standard, 2 relay changers, 2 differential analog/digital inputs and 2 non-isolated analog outputs.
What lifecycle information applies to this model?
The supplied lifecycle information is Announcement of product phase-out; exact model, version, quantity, destination and condition preference should be confirmed for an inquiry.