Product Description
Key Features
- SIPLUS ET 200 identity: SIPLUS ET 200 BU15-P16+A0+2D based on 6ES7193-6BP00-0DA0, with BU type A0.
- Supply and current capacity: Rated supply: 24 V DC. Maximum current carrying capacity: 10 A for the P1 and P2 bus and 2 A for process terminals.
- Process terminals: The unit has 16 process terminals, push-in terminals, and conductor cross-sections from 0.14 mm2 (AWG 26) to 2.5 mm2 (AWG 14).
- Installation and dimensions: Width: 15 mm. Height: 117 mm. Depth: 35 mm. The unit has 1 slot and 2 terminals with connection to the P1 and P2 bus.
- Conformal coating and protection: Conformal coating: Class 2 for high reliability according to EN 61086. Protection against fouling: Type 1 according to EN 60664-3. The unit has potential separation between the potential groups.
Technical Summary
| Product type | BU type A0 |
|---|---|
| Based on | 6ES7193-6BP00-0DA0 |
| Rated supply | 24 V DC |
| Maximum current, P1 and P2 bus | 10 A |
| Maximum current, process terminals | 2 A |
| Process terminals | 16 |
| Terminal type | Push-in terminal |
| Horizontal installation temperature | -40 °C to 70 °C; Tmin incl. condensation/frost |
| Vertical installation temperature | -40 °C to 50 °C |
| Conformal coating | Class 2 for high reliability according to EN 61086 |
| Product lifecycle | Active Product |
Frequently Asked Questions
What order number should be confirmed for this Siemens SIPLUS base unit?
Confirm the complete order number 6AG1193-6BP00-7DA0 and the nameplate designation SIPLUS ET 200 BU15-P16+A0+2D.
What supply and terminal details should be checked?
Check the rated supply of 24 V DC, 16 process terminals, push-in terminal type, and conductor cross-section range from 0.14 mm2 (AWG 26) to 2.5 mm2 (AWG 14).
What installation temperature limits apply?
For horizontal installation, the range is -40 °C to 70 °C, with Tmin including condensation/frost. For vertical installation, the range is -40 °C to 50 °C.
Does this configuration include AUX terminals?
It is without AUX terminals; the number of terminals to the AUX bus is 0.