Product Description
Key Features
- Exact product identity: SIPLUS ET 200SP AI 4xRTD/TC 2-/3-/4-wire HF, based on 6ES7134-6JD00-0CA1, with conformal coating.
- Analog input capacity: 4 analog inputs support voltage, thermocouple, resistance thermometer, and resistor measurement.
- Resolution and accuracy: Resolution is up to 16 bit; linearity error is (+/-) 0.01 % relative to the input range.
- Supply and installation: Rated supply is 24 V DC; the module is suitable for BU type A0 and A1 and has a Type A mechanical coding element.
- Diagnostics and interfaces: Channel diagnostics, wire-break detection, overflow/underflow detection, limit value alarms, and I&M0 to I&M3 are supported.
- Temperature and protection: Conformal coating is Class 2 for high reliability; horizontal installation supports -40 °C to 60 °C, with stated restrictions for +70 °C.
Applications
- Temperature measurement: The module supports temperature measurement with thermocouples and resistance thermometers.
- Voltage, resistance and process measurement: The module supports voltage measurement and resistance measurement with two-, three-, and four-wire connections.
- Stationary industrial process technology: The source specifies use in stationary industrial systems and industrial process technology under stated environmental classifications.
Technical Summary
| Product type | AI 4xRTD/TC 2-/3-/4-wire HF |
|---|---|
| Lifecycle | Active Product |
| Analog inputs | 4 |
| Resolution | 16 bit |
| Rated supply | 24 V DC |
| Input connections | 2-wire, 3-wire, and 4-wire |
| Supported BaseUnits | BU type A0, A1 |
| Input resistance | 1 MΩ for stated voltage, thermocouple, resistance thermometer, and resistor ranges |
| Conversion time per channel | 180 / 60 / 50 / (67.5 / 22.5 / 18.75) ms |
| Diagnostics | Channel diagnostics, wire break, group error, overflow/underflow, and limit value alarm |
Frequently Asked Questions
What is the exact order number and product type?
The order number is 6AG1134-6JD00-2CA1, and the product type is AI 4xRTD/TC 2-/3-/4-wire HF.
Which BaseUnits are supported?
The module is suitable for BU type A0 and A1.
What input connections are supported?
Voltage measurement and resistance measurement with two-wire, three-wire, and four-wire connections are supported.
What firmware and configuration functions are available?
FW update is possible; reparameterization and calibration are possible in RUN.