Product Description
Key Features
- Exact SIPLUS ET 200S identity: SIPLUS ET 200S EM 2AI HF based on 6ES7134-4LB02-0AB0, with conformal coating and 15 mm width.
- 2 analog voltage inputs: The module has 2 analog inputs and supports rated voltage ranges of 1 V to 5 V, -10 V to +10 V, and -5 V to +5 V.
- Input resolution and cycle time: Resolution with overrange is 16 bit including sign, with 0 to 5 V at 15 bit and ±10 V or ±5 V at 16 bit. Cycle time for all channels is max. 0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression.
- 24 V DC supply: Rated load voltage L+ is 24 V DC. Reverse polarity protection is present, and power supply to the transmitters is not present.
- Voltage measurement connections and diagnostics: The module supports connection of signal encoders for voltage measurement, shielded cable up to 200 m, hardware interrupt, wire-break diagnosis for the 1 V to 5 V measuring range only, group error, and overflow/underflow diagnosis.
- Product lifecycle status: Product lifecycle: Product cancellation.
Technical Summary
| Product function | Isochronous mode: Yes |
|---|---|
| Analog input capacity | 2 analog inputs |
| Rated load voltage L+ | 24 V DC |
| Rated input voltage ranges | 1 V to 5 V; -10 V to +10 V; -5 V to +5 V |
| Cycle time, all channels | Max. 0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression |
| Resolution with overrange | 16 bit including sign; 0 to 5 V: 15 bit, ±10 V: 16 bit, ±5 V: 16 bit |
| Input resistance | 800 kΩ for 1 V to 5 V, -10 V to +10 V, and -5 V to +5 V |
| Power loss | Typ. 0.85 W |
| Product lifecycle | Product cancellation |
Frequently Asked Questions
What order number should be confirmed for this SIPLUS ET 200S module?
Confirm 6AG1134-4LB02-2AB0; the module is based on 6ES7134-4LB02-0AB0.
How many analog inputs and which voltage ranges does it have?
It has 2 analog inputs and supports 1 V to 5 V, -10 V to +10 V, and -5 V to +5 V rated voltage ranges.
What supply and connection details should be checked?
Check the 24 V DC rated load voltage L+, shielded cable up to 200 m, and the connection of signal encoders for voltage measurement.
What resolution and cycle time should be verified?
Resolution with overrange is 16 bit including sign; cycle time for all channels is max. 0.5 ms, with the stated noise-suppression conditions.
What lifecycle status is recorded for the configuration?
The lifecycle status is Product cancellation.