Product Description
Key Features
- Exact product identity: Product type designation: IO-Link DQ 8x24VDC/2A. HW functional status: FS01.
- Digital outputs: 8 current-sourcing digital outputs with IEC 61131 type 2 output type and electronic short-circuit protection per channel.
- Load voltage 1L+: Rated value: 24 V DC, supplied from 1Us+ of the IO-Link master; permissible range: 18 V to 30 V. Reverse polarity protection is provided against destruction.
- Load voltage 2L+: Rated value: 24 V DC via M12 connector L-coded; permissible range: 20.4 V to 28.8 V. Reverse polarity protection is provided against destruction with load increasing.
- IO-Link interface: IO-Link protocol 1.1 with 38.4 kBd (COM2), minimum cycle time 2.1 ms, 0 byte input process data and 1 byte output process data per module. Port type A is supported.
- Physical and diagnostic features: 8x M12, IP65/67 protection, green channel-status LED, green/red module-diagnostics LED, and green load-voltage-monitoring LED.
Technical Summary
| Product type designation | IO-Link DQ 8x24VDC/2A |
|---|---|
| Digital outputs | 8; current-sourcing; IEC 61131 type 2 |
| Load voltage 1L+ | 24 V DC rated; 18 V to 30 V permissible range |
| Load voltage 2L+ | 24 V DC rated via M12 connector L-coded; 20.4 V to 28.8 V permissible range |
| Output current | 2 A rated at 45 °C; 1 A rated at 55 °C |
| IO-Link | Protocol 1.1; 38.4 kBd (COM2); 2.1 ms minimum cycle time |
| Process data | 0 byte input and 1 byte output per module |
| Connections | 8x M12; IO-Link device port type A |
| Protection | IP65/67 |
| Firmware version | V1.0.x |
| Product lifecycle | Active Product |
Frequently Asked Questions
What order number should be confirmed for this module?
Confirm the complete nameplate order number: 6ES7142-5AF00-0BL0.
Which firmware version is supplied for the identified module?
Firmware version: V1.0.x.
How many digital outputs does the module have?
It has 8 current-sourcing digital outputs with electronic short-circuit protection per channel.
Which connectors and IO-Link configuration should be checked?
The module has 8x M12 connections and supports IO-Link protocol 1.1 with port type A.